Now showing items 1-9 of 9

    • A 3-­DOF force measurement device for quality inspection applications of microsystems 

      Glettig, Wayne; Droz, Serge; Longchamp, Quentin; Rabe, Rodolph; Breguet, Jean-Marc (2015-01-06)
    • A three device silicon based platform for micro-assembly and characterization. 

      Cosandier, Florent; Barrot, François; Kruis, Johan; Voruz, Luc; Musy, Grégory; Droz, Serge; Giriens, Laurent; Glettig, Wayne; Dominé, Emmanuel (2016-01-06)
      In order to improve the assembly process of microcomponents, three high precision mechanisms were developed. All of them were designed and fabricated at CSEM, through a silicon etching process (DRIE). The devices are an ...
    • GaSb Swept-Wavelength Lasers for Biomedical Sensing Applications 

      Vizbaras, Augustinas; Šimonytc, Ieva; Droz, Serge; Torcheboeuf, Nicolas; Miasojedovas, Arūnas; Trinkunas, Augustinas; Bučiunas, Tadas; Dambrauskas, Žilvinas; Gulbinas, Antanas; Boiko, Dmitri L.; Vizbaras, Kristijonas (2019-11)
      Infrared spectral range between 1.7 and 2.5 ?m is of particular interest for biomedical sensing applications due to the presence of first overtone C-H stretch and a combination of stretch and bending vibrations of C-H, ...
    • GaSb-Based Swept-Wavelength Lasers for Spectroscopic Sensing Applications in the 1.7–2.5 Micron Spectral Range 

      Vizbaras, Augustinas; Šimonyt?, Ieva; Trink?nas, Augustinas; Miasojedovas, Ar?nas; Bu?i?nas, Tadas; De Groote, Andreas; Greibus, Mindaugas; Naujokait?, Greta; Andrulis, Valentinas; Martens, Daan; Droz, Serge; Torcheboeuf, Nicolas; Boiko, Dmitri L.; Dambrauskas, Žilvinas; Gulbinas, Antanas; Vizbaras, Kristijonas (2019-06)
      1.7-2.5 micron spectral region is particularly interesting for spectroscopic sensing due to the presence of strong and molecule-specific ro-vibrational absorption bands. These absorption bands correspond to the first ...
    • Long-term medical survey system 

      Chetelat, Olivier; O'Hare, Aidan; Pilloud, Pascal; Koller, Jean-Marc; Droz, Serge; Ridolfi, Andrea; Theurillat, Patrick; Renevey, Philippe; Sola, Josep; Grossenbacher, Olivier (2008-08-17)
      The European Space Agency (ESA) commissioned CSEM to design, build, validate and deliver one fully operational ground prototype of a system (LTMS2) measuring physiological parameters. The system was shipped and will be ...
    • MEMS Tunable Littman-Metcalf Diode Laser at 2.2?m for Rapid Broadband Spectroscopy in Aqueous Solutions 

      Torcheboeuf, Nicolas; Droz, Serge; Simonyte, Ieva; Miasojedovas, Arunas; Trinkunas, Augustinas; Vizbaras, Kristijonas; Vizbaras, Augustinas; Boiko, Dmitri L. (2018)
      We demonstrate a rapidly (3 ms) and widely (222 nm) tunable, compact external cavity GaSb-based diode laser with a MEMS mirror. It delivers from 8 to 24 mW power over the tuning range, showing the side-mode suppression ...
    • Miniature Flash LiDAR for Bathymetry: An Experimental Proof-of-Concept 

      Pache, Christophe; Meier, Christophe; Droz, Serge; Nguyen, David; Roulet, Jean-Christophe; Pollini, Alexandre; Houge, Torbjørn; Droz, Fabien (2021-07)
    • SOFIA secondary mirror mechanism heavy maintenance and improvements 

      Lammen, Yannick; Reinacher, Andreas; Kjelberg, Ivar; Droz, Serge; Jakob, Holger; Graf, Friederike; Lachenmann, Michael; Krabbe, Alfred (2016-07-27)
    • Swept-wavelength lasers based on GaSb gain-chip technology for non-invasive biomedical sensing applications in the 1.7–2.5 μm wavelength range 

      Vizbaras, Augustinas; Šimonyt?, Ieva; Miasojedovas, Ar?nas; Trink?nas, Augustinas; Bu?i?nas, Tadas; Greibus, Mindaugas; Naujokait?, Greta; Torcheboeuf, Nicolas; Droz, Serge; Boiko, Dmitri L.; Dambrauskas, Žilvinas; Gulbinas, Antanas; Vizbaras, Kristijonas (2018-10-01)
      The infrared spectral region beyond 1.7 μm is of utmost interest for biomedical applications due to strong overtone and combination absorption bands in a variety of important biomolecules such as lactates, urea, ...