Browsing CSEM Archive by Title
Now showing items 942-961 of 983
-
Ultra low power microelectronics for wearable and medical devices
(2017)The requirements for wearables and portable medical devices present a number of challenges in terms of integration, autonomy and connectivity, and demand a careful co-design of hardware and software to reach optimum ... -
Ultra-Lightweight PV module design for Building Integrated Photovoltaics
(2017)Most of the existing solutions for Building Integrated PV (BIPV) are based on conventional crystalline-Silicon (c-Si) module architectures (glass-glass or glass-backsheet) exhibiting a relatively high weight (12-20 kg/m(2)). ... -
Ultra-low phase-noise microwave generation using a diode-pumped solid-state laser based frequency comb and a polarization-maintaining pulse interleaver
(2015-12-14)We report ultra-low phase-noise microwave generation at a 9.6 GHz carrier frequency from optical frequency combs based on diode-pumped solid-state lasers emitting at telecom wavelength and referenced to a common cavity-stabilized ... -
Ultra-low-noise 1 µm optical frequency comb
(2014-07-31)A robust optical frequency comb is realised with an Origami-10 mode-locked femtosecond laser from Onefive GmbH generating a 100 MHz pulse train at a centre wavelength of 1047 nm. The carrier-envelope offset frequency has ... -
Ultra-short pulse non-classical light emitters utilizing multiple wide quantum wells
(2022-05-07)We report a novel ultra-short pulse emitter utilizing transient charge carrier behavior and cooperative emission in multiple wide-quantum-well heterostructures. Its optical cavity reassembles a tandem-cavity laser diode ... -
Utilization of a frequency-swept Fabry-Perot cavity quantum cascade laser for an innovative mid-IR spectrometer
(2022-05-07)We present an innovative approach for a mid-IR spectrometer comprising a commercial Fabry-Perot cavity quantum cascade laser. Utilization of the transient blue-chirped emission of such a laser the spectral fingerprint of ... -
Validation of a wrist monitor for accurate estimation of RR intervals during sleep
(2013)While the incidence of sleep disorders is continuously increasing in western societies, there is a clear demand for technologies to asses sleep-related parameters in ambulatory scenarios. The present study introduces a ... -
Validation of compliant mechanisms made by metallic Additive Manufacturing
(2022-08-29)Recent developments of compliant mechanisms built by additive manufacturing confirm their potential for highprecision applications in harsh environments. Several projects are presented, from simple flexure pivots to complex ... -
Validation of Échelle-Based Quantum-Classical Discriminator with Novelty Spad Array Sensor
(2019)Imaging with non-classical photons allows one to bypass the Rayleigh resolution limit and classical shot-noise level [1, 2]. Such schemes will operate with large photon number, produced by sources, where the entangled and ... -
Validation of échelle-based quantum-classical discriminator with novelty SPAD array sensor
(2019-03-01)Imaging with non-classical photons allows to bypass the Rayleigh resolution limit and classical shot-noise level. One step towards imaging demonstration with large photon numbers is the separation of non-classical photon ... -
Variety of non-invasive continuous monitoring methodologies including electrical impedance tomography provides novel insights into the physiology of lung collapse and recruitment – case report of an anaesthetized horse
(2014)Introduction The use of alveolar recruitment maneuvers during general anaesthesia of horses is a potentially useful therapeutic option for the ventilatory management. While the routine application of recruitments would ...