    Blood pressure measurements with the OptiBP smartphone app validated against reference auscultatory measurements

    Thumbnail
    Author
    Schoettker, Patrick; Degott, Jean; Hofmann, Gregory; Proença, Martin; Bonnier, Guillaume; Lemkaddem, Alia; Lemay, Mathieu; Schorer, Raoul; Christen, Urvan; Knebel, Jean-François; Wuerzner, Arlene; Burnier, Michel; Wuerzner, Gregoire
    Metadata
    Show full item record
    Abstract
    Mobile health diagnostics have been shown to be effective and scalable for chronic disease detection and management. By maximizing the smartphones’ optics and computational power, they could allow assessment of physiological information from the morphology of pulse waves and thus estimate cuffless blood pressure (BP). We trained the parameters of an existing pulse wave analysis algorithm (oBPM), previously validated in anaesthesia on pulse oximeter signals, by collecting optical signals from 51 patients fingertips via a smartphone while simultaneously acquiring BP measurements through an arterial catheter. We then compared smartphone-based measurements obtained on 50 participants in an ambulatory setting via the OptiBP app against simultaneously acquired auscultatory systolic blood pressure (SBP), diastolic blood pressure (DBP) and mean blood pressure (MBP) measurements. Patients were normotensive (70.0% for SBP versus 61.4% for DBP), hypertensive (17.1% vs. 13.6%) or hypotensive (12.9% vs. 25.0%). The difference in BP (mean?±?standard deviation) between both methods were within the ISO 81,060–2:2018 standard for SBP (??0.7?±?7.7 mmHg), DBP (??0.4?±?4.5 mmHg) and MBP (??0.6?±?5.2 mmHg). These results demonstrate that BP can be measured with accuracy at the finger using the OptiBP smartphone app. This may become an important tool to detect hypertension in various settings, for example in low-income countries, where the availability of smartphones is high but access to health care is low.
    Publication Reference
    Scientific Reports, vol. 10 (1), pp. 17827
    Year
    2020-10-20
    URI
    https://yoda.csem.ch/handle/20.500.12839/982
    Collections
    • Research Publications

    Browse

    All of YODACommunities & CollectionsBy Issue DateAuthorsTitlesResearch AreasBusiness UnitsThis CollectionBy Issue DateAuthorsTitlesResearch AreasBusiness Units

    My Account

    Login

    DSpace software copyright © 2002-2022  DuraSpace
    Contact Us | Send Feedback
    DSpace Express is a service operated by 
    Atmire NV