Abstract
In this work we present a method to characterize microcracks in carbon fiber reinforced polymer (CFRP) samples with a diameter up to 120 mm using quantitative grating-based X-ray dark-field imaging. In contrast to conventional microcomputed tomography (XCT), grating-based X-ray radiography and XCT provide three complementary images: (a) attenuation contrast (AC), (b) differential phase contrast, and (c) dark-field contrast (DFC). CFRP samples were subjected to low velocity impacts, followed by subsequent short beam bending tests. Using a multiscale approach, we assessed damage two- and three-dimensionally at voxel sizes of 12.5 mu m, 22.8 mu m, and 50 mu m. Since DFC delivers morphological information in the sub-pixel regime it is possible to quantify defects in relatively large samples whereas microcracks are not visible in AC images. We compared our results to ultrasonic testing showing that X-ray dark-field imaging improves defect detection in CFRPs without the necessity of small sample dimensions.
Publication Reference
Composites Part a-Applied Science and Manufacturing, vol. 115, pp. 206-214, Dec 2018.